CLB-GZDW DC Power Source Screen

Short Description:

Microcomputer controlled DC power supply panel CLB-GZDW-2/3/4 aredesigned for various electrical capacity equipment users, of which the systemconfiguration is composed of monitoring module, rectifier module, AC/DCmonitoring module, insulation monitoring module, the battery inspection module,switch quantity monitoring module, voltage reduction module, power distributionunit, accumulator and cabinets. They have the characteristic of“simpleoperation, intelligent management and high efficiency and energy saving.”


Contact:

  • 电话
  • qq
  • sns03
  • sns01
  • skype
  • 播放器
  • sns02

Product Detail

Product Tags

Microcomputer controlled DC power supply panel CLB-GZDW-2/3/4 aredesigned for various electrical capacity equipment users, of which the systemconfiguration is composed of monitoring module, rectifier module, AC/DCmonitoring module, insulation monitoring module, the battery inspection module,switch quantity monitoring module, voltage reduction module, power distributionunit, accumulator and cabinets. They have the characteristic of“simpleoperation, intelligent management and high efficiency and energy saving.”

·               They are applicablefor field of electrical power, communication, transportation, chemicalindustry, metallurgy, military, medical treatment, construction, fireprotection, etc. and users terminal. It can be used as operating power supplyand control power supply for high voltage switch, relay protection and automaticdevice

CLB-GZDW-2:
1)
With two – way AC input automatic switching toensure the normal operation of the system;
2)
The input voltage with wide range, the power grid iswell-adapted;
3)
With HZ-JK02B monitoring, LCD screen, Chinese menu,friendly and plentiful interface, the operation of the keys is simple andconvenient;
4)
With comprehensive system setup, operationinformation inquiry and various alarm functions;
5)
With Intelligent battery charge and dischargemanagement and perfect reliable temperature compensation function;
6)expandable battery inspection single set of 110 sections, insulation inspectionof 30 ways, switch quantity inspection of 32 ways
7) The system uses multi-level password authoritymanagement to limit the operation of unauthorized personnel and ensure the safeand reliable operation of the system ;
8)
The built-in RS232、RS485 communication interface have the function of  operating telemetry,telecontrol, telecommand, tele-regulatingtowardssystem through background monitoring and remote monitoring to realizeunattended operation
9)
Support four communication protocol options of RTU, CDT, MODBUS。

CLB-GZDW-3:
1)
With two – way AC input automatic switching toensure the normal operation of the system;
2)
The input voltage with wide range, the power grid iswell-adapted;
3)
With HZ-JK03 monitoring. The 5.7-inch touch screendisplay with Chinese interface, man-machine friendly interface and touchoperation;
4)
With comprehensive system setup, operationinformation inquiry and various alarm functions;
5)
With Intelligentbattery charge and discharge management and perfect reliable temperaturecompensation function;
6)
Rectifier module with electric plug, easy and fastdaily maintenance;
7)
expandable battery inspection dual sets of 110sections, insulation inspection of 240 ways, switch quantity inspection of 160ways, compatible with communication power module, inverter power module and DCconversion module
8) The system uses multi-level password authoritymanagement to limit the operation of unauthorized personnel and ensure the safeand reliable operation of the system;
9)
The built-in RS232、RS485 communication interface have the function of  operating telemetry,telecontrol, telecommand, tele-regulatingtowardssystem through background monitoring and remote monitoring to realizeunattended operation
10)
Support four communication protocol options of RTU, CDT, MODBUS。

CLB-GZDW-4:
1)
With two – way AC input automatic switching toensure the normal operation of the system;
2)
The input voltage with wide range, the power grid iswell-adapted;
3)
With HZ-JK04 monitoring, new configuration software,color 7-inch (10.4-inch) LCD display with touch operation, 32-bit true colordisplay, quick refresh speed, intuitive and humanized design which can work fora long time in the state of long light with Perfect human voice alarm system;
4)
With comprehensivesystem setup, operation information inquiry and various alarm functions;
5)
With Intelligent battery charge and dischargemanagement and perfect reliable temperature compensation function;
6) Rectifier module with electricplug, easy and fast daily maintenance;
7) With Controllable rectifier module up to 26 sets, expandable AC/DCinspection of 2 units, insulation inspection of 240 ways, battery inspectiondual sets of 110 sections, switch quantity inspection of 160 ways, compatiblewith inverter module and DC conversion module.
8) With 32M super storage space, the system has built-inUSB interface, with multiple printout system;
9)The system uses multi-level password authoritymanagement to limit the operation of unauthorized personnel and ensure the safeand reliable operation of the system;
10) The built-in RS232、RS485 communication interface have the function of  operating telemetry,telecontrol, telecommand, tele-regulatingtowardssystem through background monitoring and remote monitoring to realizeunattended operation
11) Support four communication protocol options of RTU, CDT, MODBUS, IEC

12) According to the needs of users, the system can be customized to add thefunctions of  image-text display and GPSSMS alarm

MainParameter:

project Parameter index
Rated input voltage 380VAC±20%
Rated output voltage 220VDC110VDC
Rated output current 10A15A20A30A40A50A60A70A80A90A
100A120A130A150A180A200A260A300A……
Accumulator capacity 7Ah10Ah20Ah38Ah65Ah100Ah150Ah200Ah300Ah
500Ah600Ah800Ah1000Ah1500Ah2000Ah……
Stabilized voltage precision ≤±0.5%
Stabilized current precision ≤±0.5%
Ripple factor ≤±0.1%
Grid frequency 50Hz±10%
Power factor ≥0.95%(full load output)
Dielectric strength 10MΩ2kVAC No flashover or breakdown for one minute
Working mode Work for continuous long- term
Cooling mode Intelligent temperature control type air cooling, efficient natural cooling
Audible noise ≤50dB

Environmentalcondition:

1) Altitude: not more than 2000 meters ;
2) Environment temperature: -10
~+40℃;
3) Relative humidity:
90(25)
4) Seismic intensity: not more than 8
℃;
5)
Equipment is limited to indoorwork with good ventilation;
6) The room should be free of corrode metal and harmful gases that damageinsulation

7) Install vertical inclination: not more than 5
℃;
8 The micro-controller for noiseresistant: 1000V 1μs pulse for 1minute
9)
With no strong electromagnetic interferenceand violent vibration。

System Configuration

Name Size Specification Functional specification
Monitoring module CLB -JK series Must be configured
Rectifier module CLB series
Ac/dc monitoring module CLB -JZL series
Voltage reduction module CLB -GL series
Insulation monitoring module CLB -JY series optional
Battery inspection module CLB -XJ series
Switch quantity monitoring module CLB -JD series
Inverter module CLB -NB series
DC conversion module CLB 24S/48S series
The power distribution units Configure according to user’s requirements
Battery
Cabinet body

2) Monitoring module selection

Name Type Specification Notes
Monitoring module CLB -JK02 Liquid Crystal Display
CLB -JK03 Touch screen
CLB -JK04 True color graphic touch screen
CLB -JK05T

3) Rectifier module selection

Name Type Specification Functional specification Notes
Rectifier Module CLB 22005 220VDC 5A Independently Display, query and Setting
CLB 11010 110VDC 10A
CLB 22010 220VDC 10A
CLB 11020 110VDC 20A
CLB 22020 220VDC 20A
CLB 11040 110VDC 40A

① Currentcalculation
The configuration of the rectifier module is mainlydetermined by the maximum constant load current and battery charging currentC10(battery capacity). The total rated output current of all modules should begreater than or equal to the sum of the maximum constant load current andbattery charging current of the system。IfN+1 redundancy is to be realized, one more module should be added on the basisof the original number

② Thenumber calculation
The number of rectifier moduleconfiguration is calculated according to the following two formulas.Control bus without rectifier module:

4) functional module selection

Name Type Specification Functional specification Notes
Insulation monitoring module CLB -JY02B 30 way×4 Please click detailed page 4 in parallel connection
AC/DC monitoring module CLB -JZL01A AC 2 way, DC 8 way
Battery inspection module CLB -XJ01A 22 section ×5 5 in parallel connection

Switch quantity monitoring moduleCLB -JD0132 way ×5Voltage reduction moduleCLB -GL0320-100A Inverter moduleCLB -NB1-6KVAConfigure according to user’s requirementsDC conversion moduleCLB 24S/48S24/48VDCInsulation detector  Please refer to the random instruction for details.Battery inspection instrument  signal alarm device

Distribution unit section

Name Type Size Functional specification Notes
AC Circuit Breaker optional optional Ac input on off and overload short circuit protection Configure according to user’s requirements
Dual Power Switch Ac input automatic switching and overload short circuit protection
AC Contactor Ac input is automatically switched
DC Circuit Breaker Module output, control power bus and closing power source bus output, battery power supply and overload, short circuit protection
Pointer Current Voltmeter Input/output voltage/current indication
Digital Display Current Voltmeter Input/output voltage/current display
Fusible Knife Switch Battery power on and off and circuit protection
Fuse Battery power on and off, circuit protection and fuse alarm
electric reactor Suppress harmonics and improve power quality
Lightning arrestor Protection against lightning overvoltage shock
Overvoltage protector The protection of over voltage, under voltage and default phase of AC input
Special component Realize other function

(1) Thestandard configuration is the input ac second circuit, the output dc controlpower supply bus under 65 Ah is 3 circuit, the closing power supply bus is 3circuit, the output dc control bus is 5 circuit and the closing power supplybus is 5 circuit, the current voltmeter is the pointer board meter。
(2) The configuration can be customized according to user’s requirements

6) battery selection

Type selection

Type DC Voltage Specification Ah Functional specification
Lead-acid battery 2V 7-2500Ah Maintenance-free
12V 7-200Ah
Colloid storage battery 2V 7-2500Ah Maintenance-free, long service life
12V 7-200Ah

Thestandard configuration is lead-acid batteries。

quantity configuration

System voltage Battery voltage Section number Functional specification
220VDC 2V 110 Series connection battery sets
12V 18
110VDC 2V 55
12V 9

capacity calculation

Thecapacity of the battery is determined by the maximum instantaneous load of thesystem which are in the state of power failure, and the surplus must beappropriately increased in combination with the actual situation.The systemload is divided into constant load (Izc), emergency load (Isg) and impact load(Ihz).The constant load mainly includes the frequently charged relay, signallamp and other electrical equipment connected to the DC system. The emergencyload is the load that must be power supplied by the dc system when the power iscut off due to the loss of ac power in the power substation, mainly foraccident lighting.Theimpact load is mainly the sum of the borne loads of which the short (0.1~ 0.5s)closing impact current and with its DC bus.The maximum instantaneous load is the sum of the above threeloads, namely the maximum instantaneous load of the battery Imax=Izc+Isg+Ihz,then the battery capacity =Imax/ battery discharge rate * reserve coefficient(Ah)。

(1) Thedischarge rate of maintenance-free lead-acid batteries is usually 0.1。
(2) The above calculation method can achieve the continuous discharge for 1hour of the system which is in the state of power failure

(3)
The remainingbattery capacity shall not be less than 25 of the rated capacity to avoid excessive discharge ofbattery when thebattery is closed at the end of discharge。
(4)
Considering thedecaying capacity at the end of battery aging, the reserve coefficient of 1.2is generally chosen。

7) The choice for the cabinet body

model selection guide of cabinet body

type size Functional specification notes
Standard configuration 2200x800x600

With GGD structure, computer gray standard plastic spray, The aluminum alloy frame glass door for the front side, The double door for the back side, the lighting is equipped inside the cabinet,  temperature control automatic ventilation for the top side

Height x width x depth(mm)
2260x800x600
advanced configuration 2200x800x600 With C type structure, computer gray standard plastic spray, The advanced aluminum alloy frame glass door for the front side, The double door for the back side, the lighting is equipped inside the cabinet,  temperature control automatic ventilation for the top side
2260x800x600

The structure, color and specifications can be customizedaccording to users’requirements。

surface counting

System capacity (Ah) 10~50 65~120 150~200 250~350 400~500 600~800 1000
Surface quantity of the cabinet body Single battery 1 2-3 3-4 4-5 5-6 7-8 9-10
Double battery 2 3-4 4-5 6-7 10-12 12-14 14-17

(1) Theconfiguration surface quantity of the cabinet body depends on the number ofmodules, feeder circuit number, battery capacity and dc voltage, etc. The abovecalculation is for reference only。
(2)
The batteries with a capacity above 200Ah can be installed bybattery rack

8) please refer to the page link for the instruction of system installation,commissioning, using and breakdown maintenance,
9) please refer to the page link for the instruction of batteryinstallation, using and maintaining