< img src="https://mc.yandex.ru/watch/85166581" style="position:absolute; left:-9999px;" alt="" />

Gerneral Protection circuit breaker P.G

Short Description:

The PG circuit breaker range, from 5 to 60A, (1Ph+N) or (3Ph+N), with or without earth leakage protection (300mA – 500mA or 650mA), offers the right product to fit every type of installation.


Contact:

  • 电话
  • qq
  • sns03
  • sns01
  • skype
  • 播放器
  • sns02

Product Detail

Product Tags

Gerneral Protection circuit breaker P.G

The PG circuit breaker range, from 5 to 60A, (1Ph+N) or (3Ph+N), with or without earth leakage protection (300mA – 500mA or 650mA), offers the right product to fit every type of installation.

Operating principles

Service connections are the interface between the utility and the end used customer.

They connect the customers electrical installation to the power distribution network.

Advantage

Low-cost product, suitable for conventional service connections.

Multiple rating device.

Several levels of earth leakage sensitivity.

Complies with the French NFC 61 450 standard.

Protection of the consumers installation

technical datasheet

size - mounting : diameter 4 screws

■ 2-pole 5 / 60 A  ■ 4-pole 10 / 60 A

Selection table

type

rated

current

(A)

setting

current

(A)

rated

voltage

(V)

RCD

(mA)

breaking

capicity(*)

(kA)

size

Gardv

part

number

2-pole

1 ph.

+ N

15

5/10/15

230

none

A

PG 215 000

300

PG 215 300

500

PG 215 500

30

10/15/20/25/30

230

none

4.5

A

PG 230 000

300

PG 230 300

500

PG 230 500

45

15/30/45

230

none

4.5

A

PG 245 000

300

PG 245 300

500

PG 245 500

60

30/45/60

230

none

4.5

A

PG 260 000

300

PG 260 300

500

PG 260 500

4-pole

3 ph.

+ N

30

10/15/20/25/30

400

none

4.5

A

PG 430 000

300

PG 430 300

500

PG 430 500

60

30/45/60

400

none

4.5

A

PG 460 000

300

PG460 300

500

PG460 500

safety

■ thermal compensation

  • the pole settings are not affected by the ambient temperature.

■ residual current device

  • highly reliable, self-powered system
  • immunized against voltage surges of atmospheric origin
  • uninterrupted power supply for greater user convenience.

■ prevention of overvoltage

  • the neutral pole is designed to close first and open last to maintain a fixed potential.

electrical characteristics

■ earth leakage break time

  • < 0.2 s for 1IAn
  • < 0.1 s for 2 lAn

■ earth leakage tripping

  • 300 mA, 500 mA or 650 mA, self-powered

■ operating temperature

  • - 5 ° C to + 55 ° C

■ voltage drop

  • 1 pole + neutral < 0.9 V

■ insulation resistance

  • > 2 MQ

■ dielectric withstand

  • 2 kV AC for 1 minute
  • 4 kV between poles and frame

■ tripping curve

  • C type

other characteristics

■ corrosion withstand

  • 8 days in damp chamber (CCTU4 cycle)

■ weight:

  • 2-pole : 0.6 kg  4-pole : 1.0 kg

easy operation

■ operation in all positions

■ ON/OFF control by push-button

■ rating easily changed

■ lead-sealable terminal shields

■ captive terminal screws

■ pivoting terminals

■ copper cables up to 35 mm2

■ neutral identified in blue

environment

■ IP 40 protection

Prevention of overvoltage

The neutral pole is designed to close first and open last to maintain a fixed potential.

Protection against nuisance tripping

Immunized against voltage surges of atmospheric origin

Uninterrupted power supply for greater user convenience

Display of contact position

Green indicator: contact open

Red indicator: contact closed

Safety checking

The test button may be used to simulate an earth leakage fault, thereby providing a simple way to check the system.

Easy operation

operation in all positions

ON/OFF control by push-button

rating easily changed

lead-sealable terminal shields

captive terminal screws

pivoting terminals

copper cables up to 35 mm2

neutral identified in blue

Advantages:

■multiple rating device

■ temperature-compensated

■highly sensitive earth leakage protection ■complies with international standards CEE 27, EN 60898 et IEC 1009


  • Previous:
  • Next:

  • Related Products