AC EV EU Charging Pile
Contact:
Technical Parameter
Input |
220VAC |
380VAC-3Phase |
|
Rated Frequency |
50Hz |
||
Macimum Output Current |
32A |
16A |
32 |
Rated power |
7kW |
11kW |
22kW |
MTBF |
10000h |
||
Protection Level |
IP55 |
||
Dimensions |
320mm*195mm*90mm |
||
Measurement Accuracy |
Level1 |
||
Ambient Temperature |
-20℃~+50℃ |
||
Environment Humidity |
5%~95% No Condensation |
||
Altitude |
≤2000m |
||
Executive Standard |
IEC 61851EV/IEC IEC62196-2/IEC 61439-7/IEC EN50470 |
Status indicator information
(whether the basic status is complete)
POWER |
LINK |
CHARGE |
ALARM |
Description |
RED |
GREEN |
GREEN |
YELLOW |
|
Light off |
Light off |
Light off |
Light off |
No power |
Light on |
Light off |
Light off |
Light off |
Vehicle not connected or unsuccessful connection |
Light on |
Light off |
Light off |
Light off |
Vehicle Connection Succeeded |
Light on |
Light off |
Light off |
Light off |
The vehicle is charging |
Light on |
ON/OFF |
Light off |
Flashing |
In Alarm State |
Residential EV Charger
Technical Parameter
Input |
220VAC |
380VAC-3Phase |
|
Rated Frequency |
50Hz |
||
Macimum Output Current |
32A |
16A |
32 |
Rated power |
7kW |
11kW |
22kW |
MTBF |
10000h |
||
Protection Level |
IP55 |
||
Dimensions |
320mm*195mm*90mm |
||
Measurement Accuracy |
Level1 |
||
Ambient Temperature |
-20℃~+50℃ |
||
Environment Humidity |
5%~95% No Condensation |
||
Altitude |
≤2000m |
||
Executive Standard |
IEC 61851EV/IEC IEC62196-2/IEC 61439-7/IEC EN50470 |
Screen Display Icon
Icon |
Significance |
Icon |
Significance |
|
No Warning |
|
Display animation effect indicates that it is charging |
|
Warning |
|
The charging pile is in an over-current protection state |
|
Contactor Disconnected |
|
The charging pile is under over-temperature protection |
|
Contactor Closed |
|
The charging pile is in an over-voltage protection state |
|
The electronic lock of the charging gun is open |
|
The charging pile is in an short-circuit protection state |
|
The electronic lock of the charging gun is closed (to prevent accidental removal) |
|
The charging pile is in an over-current suspension protection state |
|
Normal communication with the background |
|
The charging pile is in the protection state of over-temperature suspension |
|
Failed to connect to the vehicle, unable to start charging |
|
The charging pile is in the protection state of over-voltage suspension |
|
Normally connected to the vehicle, charging can be started |
|
The charging pile is in an alarm state |